Solar Calculator Canada

Solar Power Calculator for Cote St. Luke, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Cote St. Luke
  • GPS Coordinates: 45.477607, -73.663488
  • Elevation: 44 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Cote St. Luke: 39o
  • Average yearly irradiance: 1577.11 kWh/m2
  • Average yearly power output: 133268 kWh
Sun Path Cote St. Luke

Average yearly irradiance delivered by the Sun in Cote St. Luke is 1577.11/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 133268 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.86 88.75
February 3.56 99.79
March 4.58 142.12
April 5.08 152.52
May 5.55 171.99
June 5.5 164.93
July 5.83 180.6
August 5.72 177.19
September 4.84 145.25
October 3.45 106.85
November 2.89 86.68
December 1.95 60.43
Total yearly 1577.11

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 269.81 8364.14
February 332.72 9316.22
March 411.33 12751.2
April 434.06 13021.9
May 455.37 14116.4
June 440.45 13213.6
July 461.71 14312.9
August 456.85 14162.5
September 393.55 11806.7
October 291.91 9049.1
November 254.7 7640.98
December 177.83 5512.74
Total yearly 133268

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Cote St. Luke solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 191.41 5933.63
February 264.14 7396.02
March 364.84 11310
April 425.73 12771.8
May 479.39 14861
June 478.27 14348.2
July 495.78 15369.3
August 460.58 14277.9
September 362.86 10885.8
October 243.37 7544.49
November 188.71 5661.3
December 124.29 3853.08
Total yearly 124213

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 211.26 6548.94
February 282.36 7906.02
March 379.05 11750.4
April 431.84 12955.3
May 478.96 14847.8
June 474.94 14248
July 493.38 15294.7
August 464.54 14400.8
September 373.63 11208.8
October 256.81 7960.98
November 205.59 6167.83
December 137.71 4269.11
Total yearly 127559

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 229.27 7107.45
February 298.51 8358.23
March 390.9 12118
April 435.61 13068.3
May 476.04 14757.2
June 469.03 14070.8
July 488.47 15142.5
August 466.02 14446.5
September 382.14 11464.1
October 268.52 8324.04
November 220.81 6624.39
December 149.92 4647.56
Total yearly 130129

Cote St. Luke Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 245.41 7607.57
February 312.56 8751.6
March 400.37 12411.6
April 437.02 13110.5
May 470.7 14591.8
June 460.84 13825.2
July 481.11 14914.3
August 465 14414.9
September 388.36 11650.9
October 278.47 8632.47
November 234.33 7029.86
December 160.88 4987.35
Total yearly 131928

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.74% angle of incidence loss and -3.47% temperature and irradiance loss. This totals to about -15.5%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Humber VillageCapucinsTourellePoint EdwardCornwallis SquareBelcarraAnmoreCoteau-du-LacMercierL�ryNotre-Dame-de-l'�le-PerrotPincourtSaint-ConstantDelsonL'�le-PerrotCandiacSainte-CatherineL'�le-CadieuxRichelieuCarignanSainte-Marthe-sur-le-LacSaint-Basile-le-GrandOtterburn ParkDeux-MontagnesMont-Saint-HilaireMurdochville